Cum AC contactor agit, spiraculum internum campum magneticum generat, nucleum ferrum movens et nucleum ferreum stationarium ad se attrahunt. Hic motus systematis contactus impellit ad concurrendum cum contactibus stationariis, circuitionem perficiens. Cum gyro de-enervit, vis attractio evanescit, et reses verna nucleum ferreum movens levat, contactus separans et ambitum frangens..
| |
| |
| |
| Maxima vis motoris electrica AC 0≤55°C,400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 |
| Productum exemplar (AC linea diagram) | AX09 | AX12 | AX18 | AX25 | AX32 | AX40 | AX50 | AX65 | AX80 |
| Rated opus current AC-3 0≤55°C,400V | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 |
| Rated opus current AC-1 0≤55°C,400V | 22 | 25 | 27 | 32 | 55 | 60 | 100 | 115 | 125 |
| Exemplar Type | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 | |
| Rated current opus (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
| AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
| Tres tempus motricium AC-3 level (kw) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
| 380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
| 415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | - | - | |
| 500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | - | - | |
| 660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 45 | |
| RatedheatingcurrentIth (A) | 20 | 20 | 30 | 32 | 40 | 50 | 60 | 80 | 125 | 125 | |
| Electrical lifespan ((X) circuitus) | AC3 | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
| AC4 | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | |
| Mechanica resta ((X) circuitus) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 | |
| Contactus exemplar | 3P NO | 3P NC NO | |||||||||
| Exemplar | Ratum est vena (A) | Principalis contactus | Contactus auxiliaris | Una-phase onus virtutis (kW) | Tres tempus onus potentiae (kW) |
| CJX2-0910 | 9A | 3NO | 1NO | 1.8KW | 3.5KW |
| CJX2-0901 | 9A | 3NO | 1NC | 1.8KW | 3.5KW |
| CJX2-1210 | 12A | 3NO | 1NO | 2.5KW | 5KW |
| CJX2-1201 | 12A | 3NO | 1NC | 2.5KW | 5KW |
| CJX2-1810 | 18A | 3NO | 1NO | 3.5KW | 7.5KW |
| CJX2-1801 | 18A | 3NO | 1NC | 3.5KW | 7.5KW |
| CJX2-2510 | 25A | 3NO | 1NO | 5KW | 8.5KW |
| CJX2-2501 | 25A | 3NO | 1NC | 5KW | 8.5KW |
| CJX2-3210 | 32A | 3NO | 1NO | 6KW | 12KW |
| CJX2-3201 | 32A | 3NO | 1NC | 6KW | 12KW |
| CJX2-4011 | 40A | 3NO | 1NO 1NC | 8KW | 18.5KW |
| CJX2-5011 | 50A | 3NO | 1NO 1NC | 10KW | 24KW |
| CJX2-6511 | 65A | 3NO | 1NO 1NC | 12.5KW | 28KW |
| CJX2-8011 | 80A | 3NO | 1NO 1NC | 15.5KW | 37KW |